4-June-2015 US Belle II HW/FW Meeting

→ Pacific/Honolulu
    • 9:00 AM → 9:10 AM
      KLM: HW, FW, TargetX Tests, open issues 10m
      Slides
      Dump HS can be useful so add it to the BDAQ repository.
      Good diagnosis tool.
    • 9:10 AM → 9:25 AM
      TOP Testing: Module 01 FW 15m
    • 9:25 AM → 9:35 AM
      TOP KEK: Debugging 10m
      Slides
    • 9:35 AM → 9:40 AM
      TOP HW: Carriers, laser, SC 5m
    • 9:40 AM → 9:50 AM
      TOP boardstack hit timestamping (trigger): update 10m
    • 9:50 AM → 9:55 AM
      TOP FW: feature extraction, belle2link and overall 5m
      Slides
      Look at the FTSW clock using a scope. Also, the clock has to go straight ot the reclock on the FPGA, routing through fabric will not work.

      Looking at the HSLB schematic, we can see that the RJ45 clocks are directly going to the FPGA. There is no analog receiver so jitter cannot be cleaned. This is a big problem and this design will not work as good.

      A solution can be to make a receiver board and drop in on the way to HSLB.

      HSLB to FTSW distance : at Pitt: 10 ft,  at KEK: 5-7 both CAT-7 , one cable, no couplers. meters and they are in different crates and connected to different power stips. the common mode is going to be probably very large.

      HSLB doesnt need to know trigger and there is no B2TT interface in it, it just gets clock from there.

      Test: unplug HSLB clock and see what happens at KEK.